DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
Getting Started
2.7.3 Connecting to the RS-232 Port (Optional)
You can optionally use the RS-232 port to configure and monitor the
EF2800 system using a computer with a VT-100 or ANSI terminal
emulator. You can connect to the RS-232 port on each SM. For more
information about the configuration and management capabilities
using the RS-232 port and the Disk Array Administrator software, see
Appendix C.
You must use the RS-232 cable that came with the EF2800 or one
configured like it. The RS-232 cable is a standard 6-conductor, flatline
cable with a 3.5mm jack plug to DB9 adaptor.
N
OTE
:
Not all configurations of the EF2800 are supplied with RS232
cables, you can purchase then separately from your supplier if required.
The DB9 pinout is as follows:
The RJ-11 cable pinout is straight through (not null modem) as follows:
Configure the RS-232 port in your terminal emulator software using the
following settings:
Baud rate: 9600, 19200, 38400, 57600, or 115200; 115200 is the
EF2800’s default
Pin Function Pin Function
1 No connection 6 No connection
2 Receive (RX) 7 No connection
3 Transmit (TX) 8 No connection
4 No connection 9 No connection
5Ground
Pin Function
1Ground
2Transmit (TX)
3 Receive (RX)