DataDirect EF2800 Betriebsanweisung Seite 176

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 381
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 175
Troubleshooting and Problem Solving
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
153
10.6 Dealing with Hardware Faults
Ensure that you have obtained a replacement module of the same type
before removing any faulty module.
Replace a faulty drive with a drive of the same type and equal or
capacity.
All drive bays must be fitted with a Drive Carrier module or a
dummy carrier module in order to maintain a balanced air flow.
All the supplied plug-in power supply units, electronics modules
and blank modules must be in place for the air to flow correctly
around the cabinet.
10.6.1 Continuous Operation During Replacement
Depending on how the enclosure is set up, if a disk unit fails, it can
normally be replaced without interrupting the use of the system.
In addition, each enclosure contains two power supply/cooling
modules, either of which can maintain power and cooling to the
Subsystem while the other is replaced.
10.7 Replacing a Module
Please refer to Chapter 2, "Getting Started" on page 15 for information
on the initial installation of the plug-in modules in the EF2800
enclosure.
If the enclosure is powered up and you remove any
module, replace it immediately. If the enclosure is used
with modules or module blanks missing for more than a
few minutes, it can overheat, causing power failure and
data loss. Such use will invalidate the warranty.
!
Warning
Observe all conventional ESD precautions when handling
the modules and components. Avoid contact with
Backplane components and module connectors.
!
Warning
Seitenansicht 175