DataDirect EF2800 Betriebsanweisung Seite 175

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 381
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 174
152
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
Troubleshooting and Problem Solving
10.5 Drive Carrier Module Faults
Disk drive status is monitored by a green LED and an amber LED
mounted on the front of each Drive Carrier Module, providing the
following indications:
Drive activity - LED may be off for a length of time during power up.
10.5.1 Dummy Carrier Modules
Dummy Carrier modules must be fitted to all unused drive bays to
maintain balanced air flow.
10.5.2 Auto Start Failure
Unless otherwise selected at installation time, all drives in the
enclosure should automatically start their motors after power is
applied. If this has not occurred there is a power problem (An alarm and
power fault indication would normally be active).
N
OTE
:
The SYSTEM LED will flash green/amber.
State Green Amber
No drive fitted Off Off
Drive Power ON On Off
Drive Activity Flashes Off
Drive Fault On On
Seitenansicht 174
1 2 ... 170 171 172 173 174 175 176 177 178 179 180 ... 380 381

Kommentare zu diesen Handbüchern

Keine Kommentare