Managing Disk Drives & Enclosures
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
137
failed. On most disk drives, SMART is disabled by default by the
manufacturer.
To enable or disable SMART changes:
1. From SAM, select Manage EF2800 > General Config > Disk
Configuration. The Disk Configuration page displays.
2. Select the SMART option you want.
3. Click Change Disk Option Configuration.
4. Select Manage EF2800 > Utilities and click Rescan to have your
changes take effect.
9.1.6 Blinking a Drive LED
You can blink the LED on a specific disk drive.
To blink a drive LED:
1. From SAM, select Manage EF2800 > Utilities > Disk Drive Utilities.
The Blink Drive LED page displays listing all devices.
2. Select the disk drive whose LED you want to blink.
3. Click Blink Selected Device LED. The disk drive continues blinking
its LED until you click Unblink Selected Device LED.
9.1.7 Taking Down a Disk Drive
C
AUTION
:
This function is only for testing and could result in data loss. It
should not be used in normal operation.
The Down Drive function sets the status of a disk drive in a fault-
tolerant array to down. This forces the EF2800 to remove it from the
array and marks the array as critical. The downed disk drive is marked
as Leftover and you cannot add it back to the array. You also cannot
take down any additional disk drives in the array.
If you have a properly sized dedicated or global spare, this will cause a
reconstruct on the affected array.