Getting Started
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
31
2.7.1 Expansion Enclosures
Multiple enclosures are connected together by using SFP to SFP
approved patch cables, or SFPs and optical LC to LC cables. Up to 14
expansion enclosures can be connected to the EF2800
(Figure 33).
N
OTE
:
Loss of power to any enclosure within such a loop will cause the
loop to fail.
Power Up
Ensure that all attached JBOD enclosures are fully powered up and all
hard drives have spun up prior to powering on the EF2800 enclosure.
Power Down
Ensure that the EF2800 enclosure is powered down prior to powering
down the JBOD enclosures.
2.7.2 Enclosure Device Addressing
The EF2800 enclosure supports 15 address ranges (1 to 9, A to F). The
thumb wheel switch on the Ops panel is used to select the SEL_ID base
address.
Figure 34 below shows the device addresses for the drive slots, with
respect to different enclosure ID settings. Each table cell represents a
drive slot on the enclosure (when viewing from front). Up to 14
expansion enclosures can be daisy-chained to the EF2800 and each
enclosure must have a unique enclosure ID.
N
OTE
:
There must be a drive present in Bay 1/1 or 4/4 to enable SES
Communications to operate. Installing drives in both of these bays will
provide redundant SES communication paths.