DataDirect EF2800 Betriebsanweisung Seite 191

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 381
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 190
168
DataDirect Networks EF2800 FC RAID Storage System User Guide (V 1.0)
Troubleshooting and Problem Solving
SYS
ONLINE
FAIL
The system attempted to Put
Online a newly inserted
module, however the Put
Online request failed.
The event gives a reason why the
Put Online failed. Examine this
reason and take the appropriate
action. If the reason is DIAGNOSTIC
FAIL, a hardware problem was
found with the module. In this case,
try replacing the module with a
different one.
UNWRITAB
LE CACHE
The SDRAM cache has battery
backed-up data, and the
arrays assigned to this data
are not present.
Either determine which drives are
missing and reinstall them, or select
Ye s when asked if you want to
discard this data.
VOLT/
TEMP
WARN
The analog-to-digital
convertor monitored a
temperature or voltage in the
warning range.
Check that the fans are running.
Check that the ambient
temperature is not too warm. Check
for any obstructions to the air flow.
Figure 70. Warning Events (Continued)
Event Definition Recommended Action
Seitenansicht 190
1 2 ... 186 187 188 189 190 191 192 193 194 195 196 ... 380 381

Kommentare zu diesen Handbüchern

Keine Kommentare